4th Gen HP Mini Series Inverter with Charger 600W/1000W/1500W

Short Description:

 

Features:

♦ Smart Remote Control

♦ Support Solar Panel with MPPT Function

♦ Designed to Operate under Harsh Environment

♦ DC Start & Automatic Self- Diagnostic Function

♦ Compatible with Both Linear & Non-Linear Load

♦ Easy to Install & Easy to Operate & Easy to Solve

♦ Low DC Voltage Supports Home & Office Appliances

♦ Powerful Charge Rate Up to 120Amp, Selectable From 0%-100%

♦ High Efficiency Design & “Power Saving Mode” to Conserve Energy

♦ Battery Priority Mode, Designates the Inverter-Preferred UPS Configuration

♦ 13 Vdc Battery Recover Point, Dedicated for Renewable Energy Systems

♦ 8 Pre Set Battery Type Selector Plus De-sulphation for Totally Flat Batteries

♦ 4-step Intelligent Battery Charging, PFC (Power Factor Correction) for Charger

♦ 8 ms Typical Transfer Time Between Utility & Battery, Guarantees Power Continuity

♦ 15s Delay Before Transfer when AC Resumes, Protection for Load when Used with Generator


Product Detail

Product Tags

HP mini Series Pure Sine Wave Inverter Charger1

HP Mini Series Pure Sine Wave Inverter &Charger

♦ Ultra Low THD, Typically 7% Under Full Linear Load

♦ MPPT Solar Charger Controller Available

♦ Remote Control Available

♦ Battery Temperature Sensing For Increased Charging Precision

♦ Auto Gen Start Function For Off Grid System With Generator As Backup Power

Feature of HP Series Inverter & MPPT & Charger

Features

♦ Smart Remote Control

♦ Support Solar Panel with MPPT Function

♦ Designed to Operate under Harsh Environment

♦ DC Start & Automatic Self- Diagnostic Function

♦ Compatible with Both Linear & Non-Linear Load

♦ Easy to Install & Easy to Operate & Easy to Solve

♦ Low DC Voltage Supports Home & Office Appliances

♦ Powerful Charge Rate Up to 120Amp, Selectable From 0%-100%

♦ High Efficiency Design & “Power Saving Mode” to Conserve Energy

♦ Battery Priority Mode, Designates the Inverter-Preferred UPS Configuration

♦ 13 Vdc Battery Recover Point, Dedicated for Renewable Energy Systems

♦ 8 Pre Set Battery Type Selector Plus De-sulphation for Totally Flat Batteries

♦ 4-step Intelligent Battery Charging, PFC (Power Factor Correction) for Charger

♦ 8 ms Typical Transfer Time Between Utility & Battery, Guarantees Power Continuity

♦ 15s Delay Before Transfer when AC Resumes, Protection for Load when Used with Generator

Slide to the left for full table
HP MINI Pure Sine Wave Inverter/Charger
Electrical Specification
Inverter Output Power Rating 600W 1000W
Continuous Output Power 600W 1000W
Surge Rating(20s) 1800W 3000W
Output Waveform PureSine Wave/Same as input(Bypass mode)
Nominal Efficiency 80%(peak)
Line Mode Efficiency <95%
Power Factor 0.9-1.0
Nominal Output Voltage RMS 120Vac or 230Vac
Output Voltage Regulation ±10%RMS
Output Frequency 50/60Hz±0.3Hz
Short Circuit Protection Yes, Current Limit Function(Full after 1sec)
Typical transfer time 10ms(Max)
THD Typically<3%,Max 10% under full liner load
DC Input Nominal Input Voltage 12.0Vdc
Minimum Start Voltage 10.0Vdc
Low Battery Alarm 10.5Vdc/11.0Vdc
Low Battery Trip 10.0Vdc/10.5Vdc
High Voltage Alarm & Fault 16.0Vdc
High DC Input Recovery 15.5Vdc
Low Battery Voltage Recover 13.0Vdc
Idle Consumption-Search Mode <25W when Power Saver on
AC Charger Input Voltage Range Narrow:100-135VAC/194-243Vac
Wide:90-135VAC/164-243Vac
Input Frequency Range Narrow:47-55±0.3Hz for 50Hz,57-65±0.3Hz for 60Hz
Wide:43±0.3Hz plus for 50Hz/60Hz
Output Voltage Depends on battery type
Charger Breaker Rating(120Vac) 7A 10A
Max Charge Rate 20A to 25A+/-5A,depending on models
Over Charge Protection Shutdown 15.7V for 12Vdc
Battery type Fsat Vdc Float Vdc
Gel U.S.A 14 13.7
A,G.M 1 14.1 13.4
A.G.M 2 14.6 13.7
Sealed Lead Acid 14.4 13.6
Gel Euro 14.4 13.8
Open Lead Acid 14.8 13.3
Calcium 15.1 18.6
De-sulphation 15.5 for 4hrs
Remote Control Yes. Optional
Bypass & Protection Input Voltage Waveform Sine wave(Grid or Generator)
Nominal Voltage 120Vac 230Vac
Low Voltage Trip 80V/90V±4% 184V/154V±4%
Low Voltage re engage 90V/100V±4% 194V/164V±4%
High Voltege Trip 140V±4% 253V±4%
High Voltage re engage 135V±4% 243V±4%
Max Input AC Voltage 150VAC 270VAC
Nominal Input Frequency 50Hz or 60Hz(Auto detect)
Low Freq Trip Narrow:47±0.3Hz for 50Hz,57±0.3Hz for 60Hz
Wide:40±0.3Hz for 50Hz/60Hz
Low Freq re engage Narrow:48±0.3Hz for 50Hz,58±0.3Hz for 60Hz
Wide:45±0.3Hz for 50Hz/60Hz
High Freq Trip Narrow:55±0.3Hz for 50Hz,65±0.3Hz for 60Hz
Wide: No up limit for 50Hz/60Hz
High Freq re engage Narrow:54±0.3Hz for 50Hz,64±0.3Hz for 60Hz
Wide: No up limit for 50Hz/60Hz
Mechanical Specification Inverter Dimensions(L*W*H) 325*173*135mm/12.8*6.8*5.3〞 362*173*135mm/14.3*6.8*5.3〞
Inverter Weight 7.5KG/16.5Ib 11KG/24.3Ib
Shipping Dimensions(L*W*H) 425*230*205mm/16.7*9*8〞 475*230*205mm/18.7*9*8〞
Shipping Weight 8.5KG/18.7Ib 12KG/26.5Ib
Display Status LED
Standard Warranty 1 Year

HP mini Series Pure Sine Wave Inverter Charger 2

HP mini Series Pure Sine Wave Inverter Charger 3

On the rear panel of inverter, there are 5 DIP switches which enable users to customize the performance of the device.

Switch NO Switch Function Position: 0 Position: 1
SW1 Low Battery Trip Volt 10.0VDCFor Deep-Cycle Battery 10.5VDCFor Starting Battery
*2 for24Vdc,*for48Vdc
SW2 AC Input Range AC Source For Utility Mode For Generator Mode
230Vac HV 184-253Vac 140-270Vac
120Vac LV 100-135Vac 90-135Vac
SW3 Power Saver Auto Setting Night Charger Function Detect Load Per 3Secs
SW4 O/P Frequency Setting 50Hz 60Hz
SW5 Solar/AC Priority Setting Utility Priority Battery Priority

Low Battery Trip Volt:

The Low Battery Trip Volt is set at 10.0VDC by default. It can be customized to 10.5VDC

AC Input Range:

There are different acceptable AC input ranges for different kinds of loads. It can be customizedfrom 184-253VAC to 140-270VAC.

Load Sensing Cycle:

The inverter is factory defaulted to detect load for 250ms in every 30 seconds. This cycle can becustomized to 3 seconds thru the SW3 on DIP switch.

Frequency adjust:

The frequency of the inverter is arranged by the Sw4.The factory default configuration for 220/230/240VAC inverter is 50Hz,and 60Hz for 100/110/120VACinverter. While the output freq can be easily changed once a qualified freq is applied to the inverter.

Solar / AC Priority Setting:

Our inverter is designed AC priority by default. This means, when AC input is present, the battery will be charged first, and the inverter will transfer the input AC to power the load. The AC Priority and Battery Priority switch is available upon request. When you choose battery priority, the inverter will inverting from battery despite the AC input.HP mini Series Pure Sine Wave Inverter Charger 6


  • Previous:
  • Next:

  • Write your message here and send it to us